An uninitialised probe reports -128 (0x80 read as a signed 8-bit
integer) while the refrigeration starts up. The cloud API relays it
verbatim and the sensor reported it as a real measurement, polluting
history graphs and long-term statistics.
Readings outside -20..50 C are now treated as firmware sentinels and
the sensor reports no value, so the state is 'unknown' and the recorder
excludes it. A range check is used rather than matching -128 exactly so
sibling sentinels are caught too. Both temperature fields are validated;
previously the details.temperature fallback was used unconditionally.
The sensor deliberately reports 'unknown' rather than going unavailable:
the coordinator poll succeeded and only the reading is missing, which
matches how every other sensor here signals absent data.
Logic lives in a new HA-free temperature.py so it can be unit-tested
without the Home Assistant harness, following the keg_detection.py
precedent.
Refs: Falkvinge/hassio-integration-perfectdraft-pro#4
Co-authored-by: Cursor <cursoragent@cursor.com>