Requirements

Requirement: HA Device per PerfectDraft machine

Each PerfectDraft machine SHALL be represented as an HA Device with manufacturer "PerfectDraft", model "Pro", firmware version, and serial number from the API.

Scenario: Device registration

  • WHEN entities are created
  • THEN each entity SHALL declare DeviceInfo with identifiers based on the machine ID
  • THEN the device SHALL display the firmware version and serial number

Requirement: Temperature sensor

The integration SHALL expose the beer temperature as a sensor with device class TEMPERATURE. The sensor SHALL report a value only when the API supplies a plausible reading. A reading outside the closed range -20 °C to 50 °C SHALL be treated as a firmware sentinel rather than a measurement, because the probe reports -128 (0x80 read as a signed 8-bit integer) before it has initialised.

Scenario: Temperature reading

  • WHEN the coordinator has data AND details.displayedBeerTemperatureInCelsius is within the plausible range and is not 0
  • THEN the sensor SHALL report that value
  • THEN it SHALL have unit °C, state class MEASUREMENT, and suggested display precision 0

Scenario: Fallback to details.temperature

  • WHEN details.displayedBeerTemperatureInCelsius is absent, 0, or outside the plausible range
  • AND details.temperature is within the plausible range
  • THEN the sensor SHALL report details.temperature

Scenario: Uninitialised probe reports a sentinel

  • WHEN the machine's refrigeration has just started and a temperature field reads -128
  • THEN that field SHALL NOT be reported as a measurement

Scenario: Both sources implausible

  • WHEN neither details.displayedBeerTemperatureInCelsius nor details.temperature yields a value within the plausible range
  • THEN the sensor SHALL report None, so Home Assistant records the state as unknown and excludes it from long-term statistics
  • THEN the entity SHALL remain available, because the coordinator poll succeeded and only the reading is missing

Scenario: Non-numeric value

  • WHEN a temperature field holds a value that cannot be converted to a float
  • THEN that field SHALL be treated as absent and SHALL NOT raise an error

Requirement: Keg remaining sensor

The integration SHALL expose the keg's remaining volume as a percentage.

Scenario: Volume calculation

  • WHEN the coordinator has data
  • THEN the sensor SHALL report details.kegVolume / 6.0 * 100 rounded to 1 decimal
  • THEN it SHALL have unit %, state class MEASUREMENT, and icon mdi:keg

Requirement: Keg product ID sensor

The integration SHALL expose the numeric product ID of the keg currently fitted in the machine, extracted from the API's kegActive.keg resource reference.

Scenario: Product ID extracted from resource reference

  • WHEN the coordinator has data AND kegActive.keg holds a resource reference
  • THEN the sensor SHALL report the trailing path segment of that reference as an integer
  • THEN it SHALL have icon mdi:barcode

Scenario: No keg fitted

  • WHEN kegActive.keg is absent or empty
  • THEN the sensor SHALL report no value

Scenario: Reference is not numeric

  • WHEN the trailing path segment of kegActive.keg cannot be parsed as an integer
  • THEN the sensor SHALL report no value and SHALL NOT raise

Requirement: Keg name sensor

The integration SHALL expose the name of the tapped beer, resolved from the keg product ID through a catalog bundled with the integration at keg_catalog.json. The catalog SHALL cover every keg the PerfectDraft app can select, including discontinued kegs that may still be fitted in a machine, and SHALL contain at least 116 product IDs.

Catalog entries SHALL be observed directly from a machine reporting that product ID rather than inferred from shop listings, because the product IDs cannot be queried in bulk from the API. Entry names SHALL be the beer's name only, excluding shop-listing artefacts such as pack size, "Short Date" prefixes, or best-before dates.

Scenario: Known product ID resolves to a name

  • WHEN the keg product ID is present in the catalog
  • THEN the sensor SHALL report the catalog's name for that ID
  • THEN it SHALL have icon mdi:beer

Scenario: Unknown product ID

  • WHEN the keg product ID is not present in the catalog
  • THEN the sensor SHALL report no value

Scenario: No keg fitted

  • WHEN no keg product ID can be determined
  • THEN the sensor SHALL report no value

Scenario: Catalog unreadable or malformed

  • WHEN keg_catalog.json is missing or cannot be parsed
  • THEN the integration SHALL treat the catalog as empty and continue loading
  • THEN the keg name sensor SHALL report no value while every other entity SHALL be unaffected

Scenario: Catalog format

  • WHEN the catalog file is read
  • THEN it SHALL be a flat JSON object mapping the product ID as a string key to the display name as a string value
  • THEN keys SHALL be ordered numerically

Requirement: Connection sensor

The integration SHALL expose the machine's connectivity status.

Scenario: Connection state

  • WHEN details.connectedState is true
  • THEN the sensor SHALL report "Connected"
  • WHEN details.connectedState is false
  • THEN the sensor SHALL report "Disconnected"

Requirement: Door sensor

The integration SHALL expose the machine's door state.

Scenario: Door state

  • WHEN details.doorClosed is true
  • THEN the sensor SHALL report "Closed"
  • WHEN details.doorClosed is false
  • THEN the sensor SHALL report "Open"

Requirement: Pours sensor

The integration SHALL expose the pour count since keg insertion.

Scenario: Pour count

  • WHEN the coordinator has data
  • THEN the sensor SHALL report details.numberOfPoursSinceStartup as an integer
  • THEN it SHALL have state class TOTAL_INCREASING and icon mdi:beer

Requirement: Last pour sensor

The integration SHALL expose the volume of the most recent pour.

Scenario: Last pour volume

  • WHEN details.volumeOfLastPour is greater than 0
  • THEN the sensor SHALL report the value converted from litres to millilitres (multiplied by 1000, rounded)
  • THEN it SHALL have unit mL and icon mdi:glass-mug-variant

Scenario: No pour recorded

  • WHEN details.volumeOfLastPour is 0 or null
  • THEN the sensor SHALL report None

Requirement: Mode sensor

The integration SHALL expose the current operating mode.

Scenario: Mode reading

  • WHEN the coordinator has data
  • THEN the sensor SHALL report setting.mode (e.g., "standard", "eco")

Requirement: Firmware sensor

The integration SHALL expose the firmware version, disabled by default.

Scenario: Firmware reading

  • WHEN the coordinator has data
  • THEN the sensor SHALL report details.firmwareVersion
  • THEN the entity SHALL be disabled by default in the entity registry

Requirement: Keg freshness sensor

The integration SHALL track keg freshness as a 30-day countdown from insertion, detected client-side and persisted across restarts. A keg change SHALL be detected by monitoring the coordinator data for a pour-count reset OR an upward jump in keg volume between consecutive readings, so that a swap is recognized even when the pour count never reads 0 (e.g. the user pours immediately after swapping).

Scenario: New keg detected via pour reset

  • WHEN details.numberOfPoursSinceStartup is 0 AND details.kegVolume is greater than 5.5L AND the previous pour count was not 0
  • THEN the sensor SHALL record the current UTC timestamp as the keg insertion date

Scenario: New keg detected via refill to near-full

  • WHEN a previous volume reading exists AND the previous remaining volume was below 80% of capacity AND the current remaining volume is at least 95% of capacity
  • THEN the sensor SHALL record the current UTC timestamp as the keg insertion date

Scenario: New keg detected via large volume jump

  • WHEN a previous volume reading exists AND the current remaining volume exceeds the previous remaining volume by at least 50 percentage points of capacity (a gain of at least 3.0L)
  • THEN the sensor SHALL record the current UTC timestamp as the keg insertion date

Scenario: No false trigger on first reading

  • WHEN the integration produces its first volume reading after install or restart and no previous volume reading is available
  • THEN the volume-jump triggers SHALL NOT fire

Scenario: Detection never moves the date backward

  • WHEN any detection trigger fires
  • THEN the sensor SHALL set the insertion date to the current time only
  • THEN the sensor SHALL update its tracked previous pour count and previous volume to the current readings so the same event does not re-trigger on the next update

Scenario: Freshness countdown

  • WHEN a keg insertion date is known
  • THEN the sensor SHALL report 30 - days_since_insertion, minimum 0
  • THEN it SHALL have unit d and icon mdi:calendar-clock

Scenario: No insertion date known

  • WHEN no keg insertion has been detected since the integration was installed
  • THEN the sensor SHALL report as unavailable

Scenario: HA restart

  • WHEN Home Assistant restarts
  • THEN the sensor SHALL restore the keg insertion date, last pour count, and last volume from the previous session's state attributes

Requirement: Manual keg-change button

The integration SHALL expose a button entity that, when pressed, records the current time as the keg insertion date, providing a deterministic manual override for keg-change detection.

Scenario: Button press records insertion

  • WHEN the user presses the "Mark Keg Changed" button
  • THEN the keg freshness sensor SHALL set the keg insertion date to the current UTC timestamp
  • THEN the freshness countdown SHALL report 30 days

Scenario: Override rebaselines detection

  • WHEN the button is pressed
  • THEN the sensor SHALL update its tracked previous pour count and previous volume to the latest readings so automatic detection does not immediately re-fire

Scenario: Button entity presentation

  • WHEN entities are created
  • THEN the integration SHALL register the button platform
  • THEN the button SHALL belong to the same device as the machine's sensors
  • THEN the button SHALL have a stable unique ID following the {machine_id}_{entity_key} pattern and a translated name "Mark Keg Changed"

Requirement: Entity unique IDs

All entities SHALL have stable unique IDs derived from the machine ID and entity type.

Scenario: Unique ID format

  • WHEN entities are created
  • THEN each entity's unique ID SHALL follow the pattern {machine_id}_{entity_key}

Requirement: Entity name translations

All entities SHALL have translated names via translation_key and corresponding entries in strings.json and translations/en.json.

Scenario: Names displayed

  • WHEN HA renders the entity list
  • THEN each sensor SHALL display its translated name (Temperature, Keg Remaining, Keg Product, Keg, Connection, Door, Pours, Last Pour, Firmware, Mode, Keg Freshness)